Skip to main content
search

Displacement Digital Display

The Testech Displacement Digital Display is designed to provide accurate and real-time readouts for a variety of displacement transducers, including draw wire encoders and potentiometers. This versatile display unit seamlessly integrates with multiple types of displacement sensors, offering precise measurement and easy-to-read digital outputs.

Digital Display

The BL9648 Series Digital Display is designed to deliver precise measurement and control for various displacement sensors. This indicator is a robust and user-friendly solution for accurate position control and display in industrial settings, ensuring reliable performance and easy integration with various displacement sensors.

Key Features:

  • Power Supply: 24VDC (AC220V optional)
  • Display: Five-digit, 0.56-inch digital tube, with a range from -999,999 to 999,999
  • Magnification: Adjustable from 0.000 to 999.999
  • Pulse Input: Low level: -50V to 0.5V; High level: 3.5V to 50V
  • Contact Capacity: AC220V 1A, DC24V 1A
  • Ambient Temperature: -10°C to 50°C
  • Features: External clear terminal, relay outputs, peak display, speed counting, and parameter setting password protection
  • Customization: Supports various calibration and relay output modes

Parameter Description

 

Code Description Setting range Defaults
Pn-00 The position of the decimal point (the number of decimal places in the displayed value). 0~6 2
Pn-01 Counting frequency 0-single frequency, 1-double frequency, 2-quadruple frequency 0~2 1
Pn-02 Counting magnification, after linear calibration, this item will be invalid. 0.000~9999.999 1.000
Pn-03 The upper limit and the decimal point are defined by settings. 0~9999999 500
Pn-04 The lower limit and the decimal point are defined by settings. 0~9999999 10
Pn-05 Counting direction, 0 means positive counting. 0/1 0
Pn-06 Initial value, this item is an integer without decimal point 0~9999999 0
Pn-07 Parameter protection password, when it is not zero, the parameter is protected by password. 0000~9999 0000
Pn-08 The unit of relay reset time is second, 0.0 means no reset. Note 1. 0.0-999999.9 0.0
Pn-09 Enter the filter coefficient, 0 means no filtering, and level 5 is the strongest. 0~5 0
Pn-10 485 communication address, see communication protocol for details. 00-99 01
Pn-11 Pn-08 is 0 when the lower limit relay action mode, 0-below the lower limit action 1-above the lower limit action, but has nothing to do with the upper limit, 2-over the lower limit action, if the upper limit is reached, it will reset. If Pn-08 is non-zero, this item is invalid. 0~2 0
Pn-12 The input pulse form selects 0-quadrature code input 1-single input. For single input, both can be connected to AB. 0 0
Pn-13 485 serial port baud rate setting 600~9600 bps, Note 2 0~5 5

Speed Parameter

 

Code Description Setting range Defaults
S n-00 The position of the decimal point (the number of decimal places in the displayed value). 0~4 2
S n-01 Speed unit: 0-mm/s 1-mm/min 2-m/h 0~2 0
S n-02 Speed multiplier, the speed value can be corrected 0.000~9999.999 1.000
S n-03 The upper limit and the decimal point are defined by settings. 0~99999 300
S n-04 The lower limit and the decimal point are defined by settings. 0~99999 50
S n-05 Speed measurement mode. 0 is the instant speed; 1-5 is the speed average time, in seconds. 0~5 0
S n-06 The reset time unit of the speed relay is second, 0 means no reset, note 1.    
S n-07 When S n-06 is 0, the lower limit relay action mode is the same as Pn-11. If S n-06 is non-zero, this item is invalid.    

Wiring Definition

 

Signal Output supply Output supply External reset Draw wire displacement sensor
External terminal +12v +5v GND Reset A B A- B-
Upper terminal 9 10 11 12 13 14 15 16
                                                           
Lower terminal 1 2 3 4 5 6 7 8
External terminal L N J1 Relays J2 Relays spare
  24Vdc Normal open Normal open Custom for rs485